Multi-parameter patient monitor 6 parameter +printer

multi- parameter /6 parameters Patient monitor ECG NIBP SPO2 PR TEMP
{ Standard parameter: ECG, RESP, NIBP, SpO2, TEMP, PR. built-in thermal printer
{ 7-lead ECG waveforms display, big fonts observational interface
{ Applicable to ICU, CCU, operation, adult, pediatrics and neonatal patient
{ Full lead: I, II, III, AVL, AVR, AVF and V
{ Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
{ Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
{ Band width: 0.05Hz-100Hz(3dB)
{ Heart rate: Scope: 15 times/minute to 300 times/minutes
{ Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.
{ Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.
Analysis function should be started when using the above two kinds of function
{ Cuff gassing time less than 15 seconds
{ First-time gassing pressure: dynamic state 24kPa 180 mmHg
{ Manual selection: 9.3kPa 70 mmHg 13.3kPa 100 mmHg 16.0kPa 120 mmHg 18.6kPa 140 mmHg 20.0kPa 150 mmHg 21.3kPa 160 mmHg
{ Automatic detection period: 1 minute to 240 minutes
{ Stop size 1 min 1 min -10min , 5min(10 min -30min), 10min(30 min -90min) and 30min 90 min -240min
{ Chest impedance method or concentration of carbon dioxide at end of respiration
{ Scope of chest impedance method 0 time/minute 100 minutes/minute
{ Precision of chest impedance method time/minute
{ Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg 0.4%vol-9.9%vol
{ Detection scope of respiration rate: 2 times/minute ->60 times/minute including baby
{ Detection precision of respiration rate: 1 time/minute
{ Type: Vascular/surface temperature
Invasive blood pressure (optional)
{ Type: direct and continuous detection
{ Scope: -6.67kPa(-50mmHg) 46.67kPa(350mmHg)
{ Precision: below 13.33kPa(100mmHg) 0.27kPa(2mmHg) 13.33k
{ Input resistance: not less than 500k
{ Sensitivity of sensor: 5 V/V/mmHg
{ Accuracy of sensor: 2 Isolation voltage: 4 kV
ECG, NIBP, SPO2, TEMP, RESP, Pulse Rate, Built-in rechargeable battery, Thermal printer
Optional: Dual TEMP, Single/Dual IBP, EtCO2
United State, Canada, UK, Australia
* We may refund to unusual mailing address account.
* We are not responsible for wrong or undeliverable address.
3: Pls offer home or mobile phone when the item's Value exceed 100(USD,EUR,AUD,GBP)
* we will really appreciate that you can contact us first before leaving a negative feed back, we will find a solution to meet your requirement and enhance the satisfaction.
* 2. We will refund the money to you when we get the return items. Or replace item for you.
* If you have any question pls feel free to contact
* Email: ****@gmail.com
* MSN: ****@gmail.com
Multi-parameter patient monitor 6 parameter +printer