Ecg holter system 3 channel holter recorder/analyzer

TLC9803 3 Channel Holter ECG System Introduction The TLC9803 Holter system is composed of the ECG recorders, a computer system, a laser printer and the software. The recorder has build-in flash storage media that increases its memory capacity. The software of the system is checked by AHA and MIT data, which ensure its accuracy.
We are glad to send DOMO of this device if you enquiry it.
ECG Holter System-3 Channel Holter Recorder and Analyzer
v 12-lead Color LCD Holter recorder
v Fully programmable, high Fidelity
v Channel: 3 digital recording channels for 12-lead
v Frequency response: 0.05-60Hz
v Recording time: 24 hours, full disclosure, no data compression, 12-lead ECG
v Storage: 2G built-in flash memory
v LCD display: ECG waveform and lead number
v Weight: 75g (battery not included)
v Lead: 10 wire patient cable (I, II, III, aVR, aVL, aVF, V1~V6)
Apply Demix technology, ensures the accuracy of QRS templates, includes N (Normal), V (Ventricular Ectopy), S (SVE), U (Unknown), P (Pacemaker),
A (Artifact). All the templates can be combined or separated as individual beats. beats can be superimposed. Weak signal can be identified such as P wave.
VE, SVE, aberrant beats, V-Tach, V-Pair, V-Bigeminy, Tri-geminy etc..
HRT is the most powerful ECG-related risk predictor for assessing the death risk following myocardial infarction. The predictive value is comparable with
Unique pacemaker analysis is suitable for various models i.e. AAI, VVI, DDD, DDR pacemakers.
v HRV (Heart Rate Variability) Analysis
Time domain and Spectral domain HRV analysis, superlower HRV analysis.(Heart Rate Variability is analyzed in both Time Domain and Frequency.The top of the HRV display shows the Poincare-Lorenz scatter plots. The lower left
shows the Frequency power graph. The range boundaries for LF, LF and HF can be adjusted. The lower right shows the Time Domain histogram. Day and
night times can be entered for Sleep Apnea and for A-Fib.)
v Atrial Fibrillation and Atrial Flutter Analysis
v Atrial Fibrillation is very important for the cardiologist concern. Holter ECG is an excellent test to detect transient A-Fib.
v OSAS (Obstructive Sleep Apnea Syndrome) Analysis
Using Holter test to detect the OSAS earlier and cost-saving.
ST analysis trends, form and support report, identify ischemia location.
v TWA (T-wave alterans) Analysis
Unknown for the past 40 years, T-Wave Alternans (TWA) in excess of 20 micro-volts have been in Holter recordings but have been undetected. TWA is
a strong predictor of V-Tach and other serious cardiac abnormalities. It takes less than 10-seconds to do a complete 24 hours TWA analysis.
You can check for TWA anywhere in teh 24hours ECG file. Not only can you detect TWA in the ECG file, this software lets you view the ECG showing
the actual TWA, so that you can verify and validate the presence of real TWA.
The TWA algorithm detects two modes of TWA. Mode 1 is the beat-to-beat change in T-Wave amplitudes exceeding 20 micro-volts, as shown in the
adjacent picture. Mode 2 is the gradual up and down changes of T-wave amplitudes over a series of several beats..
Countries.Satisfaction Guaranty:
Damage during installation is not considered defect or warranty. All items carry a 1 year manufacturers warranty.
if you found any problem in use please contact to us,We will try our best slove it.
Return Policy: Return is acceptable in 7 days of receipt.
Return item must be in original conditions, include package.
www.fda.gov/cdrh/industry/support/index.html
We are a distributor of this item Email: ****@126.com
Haihua commercial center 502 room
38 Wuma Road, Wenzhou, china
Ecg holter system 3 channel holter recorder/analyzer